208
The Pump Calibration Wizard automatically counts up to the amount that you specified in
. The button will turn red and display STOP while the product is being dispensed, as
shown at left.
When the procedure is finished, the button will again turn green, as shown left.
Press NEXT to continue.
Note: You may press the Reset button if you wish to start the calibration procedure over.
7. Enter Actual Dispense Amount
Enter in the actual amount of the product that was dispensed.
Press NEXT to continue.
8. Calibration Complete
The Pump Calibration number appears. You may either:
- Repeat the calibration by pressing the Repeat Calibration button.
- Press Finish to complete the calibration and exit the Pump Calibration Wizard.
The New Injection Pump Calibration Number now appears in the Pump Calibration window, as shown at
left.
C
ONFIGURING
S
ELF
-P
ROPELLED
S
PRAYER
(D
IRECT
C
OMMAND
)
The following figures and text represent the complete process to configure a self-propelled sprayer
control system. From the Configuration Tab, press the Add button, and the Operating Configuration
Wizard appears, as shown.
1. Select Equipment Configuration Type
Select Single Product Application from the on-screen dialog.
Press NEXT to continue.
2. Select Vehicle
Press New to create a new vehicle.
3. Create New Vehicle
Select Self-Propelled Sprayer from the Vehicle Type drop-
down list box.
Press NEXT to continue.
4. Enter Vehicle Information
Use the on-screen keyboard to enter names for the Vehicle Make and Model.
Press NEXT to continue.
5. Enter Full Swath Width
Enter the full width of the spray boom expressed in feet or meters for metric applications.
Press NEXT to continue.
6. Enter Number of Boom Sections
Enter the total number of boom sections.
Press NEXT to continue.