beautypg.com

Machine specific configurations, Achine, Pecific – Ag Leader InSight Ver.8.0 Users Manual User Manual

Page 209: Onfigurations

background image

195

A

PPLICATION

M

ACHINE

S

PECIFIC

C

ONFIGURATIONS

Note: The following section describes configuration procedures that are particular to specific configuration
scenarios. These procedures are provided as examples; your own machine’s configuration may vary.

A

DDING A

S

ERIAL

-C

ONTROLLED

S

INGLE

P

RODUCT

C

ONFIGURATION

The following procedure describes how to create a serial-controlled configuration for a single liquid
product as applied by a self-propelled sprayer.

• To see a menu detailing serial control configuration options, see

“Serial Control Menu Tree” on page

169

.

• For an explanation of how to create a serial-controlled configuration with a flow meter, see

“Adding a Single

Product Application with Flow Meter” on page

197

.

• For an explanation of how to create a multi-product configuration that includes a DirectCommand and serial-

controlled application controllers, see

“Adding a Multiproduct Configuration for DirectCommand and a Serial

Controller” on page

199

.)

1. Select Single Product

To add a new serial-controlled configuration press the Add button
on the Configuration Tab. The Operating Configuration Wizard
appears, as shown at left.

Use the drop-down list to select this configuration to apply to a
Single Product Application.

Press NEXT to continue.

2. Select Vehicle

Select the Vehicle to be used in the configuration from the drop-
down list. If a new vehicle needs to be made, press the New

button.

Press NEXT to continue.

3. Create New Vehicle

The Vehicle Setup Wizard appears. Since this procedure describes how to configure a self-propelled
sprayer, you may select Self-Propelled Sprayer from the Vehicle Type list box.

Press NEXT to continue.

4. Enter Vehicle Information

Use the keyboard buttons to enter names for the Vehicle Make and Model.

Press NEXT to continue.

5. Enter Full Swath Width

Enter the full width of the spray boom expressed in feet or meters for metric applications.

Press NEXT to continue.

6. Enter Number of Boom Sections

Enter the total number of boom sections.

Press NEXT to continue.

7. Enter Boom Section Widths from Left to Right

The display automatically divides the boom into equal length sections. Select individual sections and use
the on-screen keypad to edit boom section lengths if needed.