beautypg.com

Glossary of application settings, Configuration settings, Speed input settings – Ag Leader InSight Ver.8.0 Users Manual User Manual

Page 281: Automatic swath control settings, Lossary of, Pplication, Ettings

background image

267

A

PPLICATION

G

LOSSARY OF

A

PPLICATION

S

ETTINGS

Configuration settings

• Rate Outside of Field
Rate that will be used outside of the field boundary. Zero stops product application. Last Good uses the
previous rate before exiting the boundary. Rx Default uses the default rate written in the prescription file
loaded.

• Rate Display Smoothing
Determines how the feedback from the control channel’s rate sensor will be displayed on the run screen.
When checked, the display will show the target rate when the application rate is within 10% of the target
rate setting. When unchecked the display will show the raw feedback from the rate sensor.

• Minimum Flow
This setting is used to maintain a consistent spray pattern. The display will not allow flow to drop below the
entered setting. Set to flow at the lowest operating pressure for the selected spray tips with all sections on.
When spraying with one or more boom sections off, the display automatically reduces the minimum flow
setting according to the reduced spray width. To adjust this setting, select the keyboard button and enter
the desired numeric value.

• Controller Time Delay
Compensates for any delay in the control system when changing between different product flow rates
during variable rate application.

Speed Input Settings

• Primary Speed Source
Main speed input source used by the display.

• Backup Speed Source
If the primary speed source fails, the display will use the backup if one is available.

• Manual Speed
If both of the speed input sources are unavailable, manual speed can be used in order for the control
channel to provide application. Manual speed setting for use during static machine testing or by the control
system in the absence of primary and backup speed signals.

Automatic Swath Control Settings

• Turn-On Look-Ahead
Determines how far ahead the display looks to turn the swath sections back on. This setting compensates
for any delay in the product control system when the sections are turned on.

• Turn-Off Look-Ahead
Determines how far ahead the display looks to turn the swath sections off. This setting compensates for
delay in the product control system when the boom sections are turned off.

• Outside Boundary Option
Determines the behavior of the sections when exiting the field boundary or prescription-mapped area.

• Coverage Option
Based on the coverage option selected, this setting determines the behavior of the swath section when
entering/exiting an already applied area or field boundary. Options available include: Minimize Skip,
Minimize Overlap, and User Defined Percentage.