Ag Leader InSight Ver.8.0 Users Manual User Manual
Ag Leader Equipment
Table of contents
Document Outline
- General Information
- Introduction
- Company Profile
- About the Display
- Service
- Display Uses
- Features
- Data Card Usage
- Color Touch Screen
- CAN-bus Technology
- Technical Specifications
- Upgrades
- Product Registration
- Diagrams Reference
- Conventions Used in this Manual
- Cautions And Warnings
- Cross-References And Web Links
- Viewing this manual online
- How to find information you’re looking for
- Installation Instructions
- Mounting The Display
- Display Hardware
- Fuse Installation and Replacement
- Power Up
- Introduction
- Setup
- GPS
- Guidance
- Guidance Tab
- External Lightbar
- TSIP Lightbar Settings
- Operating The Display
- Autopilot Interface
- Vehicle Profile Management
- Autopilot Functions
- Autopilot Tab and Lightbar
- Using the Lightbar
- Autopilot Trim and Nudge Settings
- Nudge Settings
- Trim Settings
- Autopilot Guidance Options
- Autopilot Re-Mark A
- Shift Pattern
- Adjust Autopilot Steering
- Autopilot Guidance Operation
- About Guidance Patterns
- Center Pivot
- Pattern Import/Export
- Set New Pattern
- Pause and Resume a Pattern
- Save Pattern
- Load Pattern
- Reset Existing Pattern
- Reset New Pattern
- Remove Patterns
- Tillage
- Planting
- Planting Setup Tabs
- Creating A New Configuration
- Configuration Basics
- Adding A New Area Logging (Site Verification) Configuration
- Adding A New Rate Control/ Logging Configuration
- Adding a Multi-Variety Planting Configuration
- Adding an Additional Equipment Configuration
- Configuration Settings
- Automatic Swath Control Settings
- Row Shutoff Look-Ahead Numbers
- AutoSwath Notes
- Checking AutoSwath Performance for Row Shutoff
- Fixing Overplanting and Underplanting in AutoSwath
- Calibrate Distance
- Auxiliary Input Settings (Switch Mapping)
- Auxiliary Input Settings Window
- Add Auxiliary Input Settings
- Vehicle Tab
- Vehicle Tab - Advanced Settings
- Implement Tab
- Implement Tab - Advanced Settings
- Controller Tab
- Controller Tab Settings
- Controller Settings for Stepper Seed Rate Motor Drives
- Controller Settings for Hydraulic Seed Control
- Hydraulic Seed Controller Settings for Specific Planters
- Hydraulic Seed Meter Calibration Numbers
- Controller Settings - Auxiliary Tab
- Gear Ratio Calculations for Seed Rate Motors
- Gear Ratio Drawing - For Single Motor Drive
- Gear Ratio Drawing - For Multiple Drive Combinations
- Seed Ratio Calculation Example Procedure
- Gear Ratio Drawing - For John Deere Pro-Shaft™ Drives
- Adding A New Controller
- Product
- Machine-Specific Configurations (For SeedCommand™)
- Row Shutoff Configuration
- Hydraulic Seed Control Checklist
- Stepper Seed Rate Control Checklist
- Seed Tube Monitor Module
- KINZE Planter Monitor
- KINZE Population Monitor Configuration
- KINZE Planter Monitor Setup
- KINZE Planter Configuration
- KINZE Planter Sensor Configuration
- Muxbus Sensor Detection (for KINZE Planter Monitor)
- Sensor Information (for KINZE Planter Monitor)
- KINZE Seed Monitor Alarms
- KINZE Magnetic Coil Speed Sensor Calibration
- KINZE EdgeVac Calibration
- Run Screen Operation
- Run Screen Main Tabs
- Area and Rate Logging/ Control
- Field Button (While Not Logging)
- Region Button
- Field Button While Logging
- Site Verification Display Items
- Viewable Maps
- Map Legend
- Run Screen Operations for specific configurations
- Row Shutoff, Run Screen Operation
- Hydraulic Seed Control on Run Screen
- Stepper Seed Rate Control, Run Screen Operation
- Seed Tube Monitor on Run Screen
- KINZE Population Monitor on Run Screen
- Diagnostic Button
- Troubleshooting
- Application
- Miscellaneous Items Reference
- Application Setup Tabs
- Creating A New Configuration
- Configuration Tab - Advanced Settings
- Vehicle Configuration Tab
- Vehicle Tab - Advanced Settings
- Implement Configuration Tab
- Adding a New Implement
- Implement Tab - Advanced Settings
- Controller Tab
- Controller Tab - Advanced Settings
- Product Tab
- Product Options
- Product Settings
- Product Type description
- Restricted Use Pesticide Setup
- Tank Mix Setup
- Dry (Granular) Fertilizer Blend Setup
- Machine Specific Configurations
- Adding a Serial-Controlled Single Product Configuration
- Adding a Single Product Application with Flow Meter
- Adding a Multiproduct Configuration for DirectCommand and a Serial Controller
- Adding a Direct Injection Configuration
- Priming an Injection Pump
- Calibrating an Injection Pump
- Configuring Self-Propelled Sprayer (DirectCommand)
- Granular Spinner (DirectCommand)
- NORAC UC5 Setup
- Run Screen Operation
- Field Button (While Not Logging)
- Field Button (While Logging)
- Run Screen - Main Tabs
- Application Tab - Site Verification
- Application Tab - Flow Meter
- Application Tab - Serial Controller
- Direct Command Run Screen Examples
- Application Tab - Liquid Application for DirectCommand
- Application Tab - Spinner Spreader
- Application Tab - Strip Till
- Application Tab - Direct Injection
- Boom Height Tab - NORAC UC5 Spray Height Controller
- General Application Tabs
- Field Notes Tab
- Map Tab
- NORAC UC5 Run Screen Environment
- Rate Control/Logging Display Items
- Viewable Maps
- Map Legend
- OptRx Crop Sensor Module
- About OptRx
- Remote Sensing Explained
- How the Active Light Sensor Works
- OptRx Sensor Cable Installation
- OptRx Installation Checklist
- OptRx Crop Sensor Configuration
- Create an OptRx V.I. Reference Value
- Scan a Reference Strip
- Recording a Reference Value
- Crop Sensor Settings
- Crop Sensor Tab settings
- Crop Sensor Setup
- Sensor Setup
- Granular Application Controls
- Strip-Till
- Liquid Application Controls
- Automatic Swath Control
- Application Reporting
- Liquid Container Level Tracking
- Variable Rate Product Application
- System Diagnostic Button
- Troubleshooting
- Troubleshooting DirectCommand Liquid Applications
- Boom indicators on the run screen do not turn blue.
- Boom indicators on the Run screen of the display turn blue, but the booms do not open.
- Boom valves pause up to 5 seconds before turning on by manual control.
- Booms will not turn on when the foot pedal is on.
- No “As Applied” rate
- Rate is erratic
- Erratic behavior from the flow meter and boom valves.
- No boom pressure at the start of the field.
- AutoSwath feature not shown.
- AutoSwath checked on, but booms will not turn on.
- Booms turn on in the middle of the pass.
- Rate not responding (error flashing)
- Booms turn on when outside of the boundary.
- Booms turn on for a split second in the headlands
- Troubleshooting Direct Injection Configurations
- Direct Injection: Pump Doesn’t Run
- Direct Injection: Pump Runs Full Speed
- Direct Injection: Application Error
- Direct Injection: Discharge Flow Sensor Error
- Direct Injection: Inlet Restriction
- Troubleshooting DirectCommand Granular Applications
- Run screen Granular channel(s) green light spreader indicator will not turn on
- Master switch will not turn on when the foot pedal is on.
- AutoSwath turns on the booms too fast or too slow.
- AutoSwath feature is not shown
- AutoSwath is checked on, but the spreader will not turn on.
- Conveyor turns off in the middle of the pass
- Total Applied does not match Actual Weight Applied
- Rate not responding
- Troubleshooting Serial Control Applications (Liquid and Granular)
- Rate changes on the display, but not on the controlled console.
- Troubleshooting Serial Control Applications (Liquid Only)
- The display rate and serial-controlled rate do not match
- Troubleshooting Serial Control Applications (Granular Only)
- The display rate and serial-controlled rate do not match
- Glossary of Application Settings
- Configuration settings
- Speed Input Settings
- Automatic Swath Control Settings
- Auxiliary Input Settings
- Controller Settings
- Controller Settings: Direct Injection Pump Calibration
- Field Notes
- Run Screen
- Fertilizer Default Product Settings
- Fertilizer Default Product Settings (continued)
- John Deere Specific Instructions
- Control Valve Settings
- Liquid Product Control Valve Configuration Options
- Servo Control Valve Settings (By Manufacturer)
- Control Valve Settings for Self-Propelled Sprayers
- Liquid Servo Settings Description
- Liquid PWM Control Valve Settings Description
- Spinner Spreader Servo Settings Description
- Spinner Spreader PWM Control Valve Settings Description
- Spinner Speed PWM Valve Settings Description
- Dickey John NH3 Conversions
- Harvest