1. Read Static Calibration warning

A warning appears, advising to disable the blower fan circuit and
prepare to catch any product dispensed in an appropriate container.

Press OK.

2. Select Metering Circuit to Calibrate

The CFR Calibration Wizard appears. Choose the desired channel to
calibrate, and press NEXT.

3. Enter Dispense Amount

Use the numeric keypad to enter the amount of product to be
dispensed into the container, and press NEXT.

4. Enter Simulated Target Rate

Use the numeric keypad to enter a simulated target rate, shown in pounds per acres. Press NEXT when
finished.

5. Start Target Rate Countdown

Press the green Start button to begin the target rate countdown. As the countdown is started, the button
will turn red and state Stop.

When the countdown is complete, press the NEXT button.

6. Enter Actual Dispense Amount

Enter the actual dispense amount, in pounds.

.

Note: The CFR will be calculated from the actual product amount dispensed.

7. Calibration Complete

A message appears, stating that your calibration is complete, and showing the CFR amount, in cubic
feet per revolution. Either:

Press the Repeat Calibration button, or

Press Finish.

In-field CFR Calibration Procedure (Strip-Till)

The In-Field CFR Calibration procedure performs an automated routine to adjust the calibration number
for the selected metering circuit. This calibration is performed if there is a difference between the amount
of product logged as compared to what was actually applied. To do an In-Field Calibration procedure,
press the In-Field Calibration button on the Strip-Till Control window. The In-Field CFR Calibration
Wizard appears, as shown.