Motion Control

11.3.1 Prerequisites for Position Control

11-36

Position Buffers

The position buffers are a collection of position data stored in the SVA Module, and a maxi-
mum of 256 points can be stored for each axis. They are used for the position data when
POSITIONING and other motion commands are executed. Continuous operation is enabled
by storing the position data in advance, and by using a simple program that only specifies
the points.

Using the Position Buffers

By first storing in the position buffers the position information for a machine whose operat-
ing pattern has been determined in advance, continuous positioning of up to 256 points is
enabled simply by refreshing the buffer pointer at the completion of a single-block opera-
tion.

Reading/Writing Position Buffers

1. Writing to Position Buffers

        

  

1 
2 
3 





256  

OWC001

OLC012

OWC021

OLC038
OLC03A

ILC028

CPU

SVA

RUN Command Settings

Position Reference Setting

Motion Control Flags

Position Buffer Access Number

Position Buffer Write Data

Position Buffer Read Data

Position buffer

CPU

SVA

123456

OWC021

OLC038

OLC03A

1 
2 
3 






256  

96



123456

96

Position buffers