10.2 Troubleshooting

10-17

10

„

A.84

A.84: Absolute Encoder Data Error

Display and Outputs

Note: OFF: Output transistor is OFF (alarm state).

Status and Remedy for Alarm

„

A.85

A.85: Absolute Encoder Overspeed

Display and Outputs

Note: OFF: Output transistor is OFF (alarm state).

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

OFF

OFF

OFF

OFF

Cause

Remedy

A

Absolute encoder misoperation.

Replace the servomotor is the problem
occurs often.

B

Circuit board (1PWB) defective.

Replace SERVOPACK.

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

OFF

OFF

OFF

OFF

Pn002.2 = 1

A

B

Pn002.2 = 1

A

B

At power ON

Pn002.2 = 0 or 2

During operation