Page 428

background image

Motion Control

11.2.5 Zero Point Return Mode

11-26

Operating Conditions

Input a limit switch signal width at least twice that of the high-speed scan setting.

Ladder Logic Program Example

Fig 11.15 RUN Commands (DWG H01)

The example in the above illustration has been greatly simplified. In actual operation, each
register can be controlled from the user program.

H0110

RUNMOD

OWC0C0

LSDEC

OBC0C1F

IB00100

RUN

OBC0C10

RUNPB

IB00110

DEND

Set the zero point return mode to

ON.

IB00100: Limit switch signal (DECLS)

Driver RUN command (RUN)

When IB00110 turns ON, the zero

point return operation starts. When

the zero point return operation is com-

pleted, the zero point return comple-

tion signal IBC0C0F (ZRNC) turns

ON.