11.3 Position Control

11-31

11

The following table shows the meanings of the above parameters and gives some setting
examples.

Table 11.8 Electronic Gear Parameters and Constant Table

Servo Fixed

Parameter No.

Name

Description

Initial

Value

No. 19

Distance
Travelled Per
Machine Rotation

• This parameter shows the load travel distance for each rotation of the

load axis. Sets the load travel distance value divided by the mini-
mum reference unit.

• Some examples of the load travel distance are shown below.

10000

Distance Travelled Per

Machine Rotation

Load Configuration Examples

P [mm]

Ball
screw

360 [

。 

]

Round
table

D [mm]

Belt

• No. 19 setting range: 1 to 2

31

- 1 [1 = 1 reference unit]

Setting Examples

• Load travel distance per load axis rotation = 12 mm
• Minimum reference unit = 0.001 mm [reference unit: mm, digit

number after decimal point: 3]

No 19

,

=

負荷軸1回転あたりの負荷の移動量

最小指令単位

Load travel distance for each rotation
of the load axis

Minimum reference

No. 19=

P

P = Ball screw pitch

One rotation = 360°

π

D

π

D

を設定します。

12000

0.001mm

12mm

No.19

=

=