beautypg.com

Status and remedy for alarm, A.7a, Display and outputs – Yaskawa MP940 User Manual

Page 381

background image

SERVOPACK Inspection, Maintenance, and Troubleshooting

10.2.1 Troubleshooting Problems with Alarm Displays

10-14

Status and Remedy for Alarm

„

A.7A

A.7A: Heat Sink Overheated

Display and Outputs

Note: OFF: Output transistor is OFF (alarm state).

ON: Output transistor is ON.

Status and Remedy for Alarm

Note: This alarm display tends to occur only with a SERVOPACK of 30 W

to 1000 W.

Cause

Remedy

A

Frequently turning the main circuit power
ON/OFF.

Do not repeatedly turn ON/OFF the main
circuit power.

B

Circuit board (1PWB) defective.

Replace SERVOPACK.

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

ON

ON

ON

OFF

Cause

Remedy

A

The ambient temperature of the SERVO-
PACK exceeds 55ºC.

Alter conditions so that the ambient
temperature goes below 55ºC.

B

The air flow around the heat sink is bad.

Follow installation methods and pro-
vide sufficient space as specified.

C

Fan stopped.

Replace SERVOPACK.

D

SERVOPACK is operating under over-
load.

Reduce load.

E

SERVOPACK defective

Replace SERVOPACK.

A

B

When main circuit power

turned ON or OFF

At power ON

E

A.B.C.D

During servomotor operation

When control power turned ON

A, B, C, D