beautypg.com

8 mp940 initialization, Wire and check the cables. refer to, Turn on the power to the sgdh servopack and mp940 – Yaskawa MP940 User Manual

Page 227: 7 connections and wiring, 1 dip switch settings

background image

5.8 System Startup

5-55

5

„

Operation Using MP940 Analog Output

SERVOPACK (SGD) to Switch Box Connections

„

Connecting a Variable Resistor to the V-REF Terminal of the SGDH
SERVOPACK as a General AI Input

5.8.8 MP940 Initialization

The initialization procedure when mounting an SGDH SERVOPACK to the MP940 is
shown below.

1. Mount the MP940 to the SGDH SERVOPACK.

Refer to 5.8.5 Mounting the MP940 Module.

2. Wire and check the cables.

Refer to

5.8.7 Connections and Wiring.

3. Clear the MP940 memory using the DIP switch (turn ON INIT and TEST only).

Refer to

Memory Initialization

in

3.2.1 DIP Switch Settings

.

4. Turn ON the power to the SGDH SERVOPACK and MP940.

1

AO

V-REF

26

AO-GND

SG

4

PA+

PAO

5

PA-

/PA

29

PB+

PBO

30

PB-

/PB

3

4

20

21

22

23

IO

CN1

14

DI_0

39

DI_1

15

DI_2

40

DI_3

16

DI_4

13

24V

24 VDC

MP940

SGD

6

GND

19

SG-PG

Switch box

Start
Pause
Stop

Alarm reset

5

6

V-REF

SG

CN1

SGDH

3

1

12V