Yaskawa MP940 User Manual
Page 258

Parameters
6.3.2 Motion Setting Parameter Details
6-18
Table 6.2 Motion Setting Parameter Details
No.
Name
Register
Number
Bit Name
Description
Default
1
RUN Mode
Settings
(RUNMOD)
OWC000
Set the RUN mode, such as Control Mode and Alarm Reset. The bit configuration is
shown below.
Bit
0
Speed Refer-
ence Output
Mode (NCON)
Used to set Speed Reference Output Mode.
0
1
Torque Refer-
ence Output
Mode (TCON)
Used to set Torque Reference Output Mode.
0
2
Position Control
Mode (PCON)
Used to set Position Control Mode.
1
3
Phase Control
Mode (PHCON)
Used to set Phase Control Mode
0
4
Zero Point
Return Mode
(ZRN)
Used to set Zero Point Return Mode.
0
5
Phase Control
Test Mode
(PHTEST)
Set whether the results of phase reference calcula-
tions and PI control calculations are valid or not in
Phase Control Mode.
0: Not valid
1: Valid
When Not Valid is selected, this parameter func-
tions much like the Speed Reference Output Mode
with the Filter Time Constant and Acceleration/
Deceleration Time Constant set to 0.
0
6
Alarm Clear
(ACR)
The following monitor parameters will be cleared
when this bit turns ON.
• IWC000 RUN Status: Error Counter Over (bit 0)
and Motion Setting Parameter Setting Error (bit
1)
• Alarms (ILC022)
0