9.2 System Errors

9-15

9

Table 9.6 User Operation Error Status - 4

„

System Service Execution Status

Table 9.7 Latest Data Trace Record Number

„

System I/O Error Status

Error Code

Error Contents

User

System Default

Integer - Real
Number Oper-
ations

1000H

Index error within DWG

No

Re-executed with i, j = 0

2000H

Index error within function

No

Re-executed with i, j = 0

Integer Opera-
tion

x060H to
x077H
(x = 1, 2)

Index error within integer system func-
tion

No

The A register remains the same.

x06DH: PI

x06DH: PD

x06FH: PID

x070H: LAG

x071H: LLAG

x072H: FGN

x073H: IFGN

x074H: LAU

x075H: SLAU

x076H: FGN

x077H: IFGN

Name

Register No.

Remarks

System Error Count

SW00090

System Error Code

SW00091

Failure Occurrence Count

SW00092

Failure Restoration Count

SW00093

Reserved by System

SW00094 to
SW00097

(Not used.)

Existence Of Data Trace Definition

SW00098

Bit 0 to 3 = Group 1
Definition exists = 1, No definition = 0

Data Trace Execution Status

SW00099

Bit 0 to 3 = Group 1
Trace executing = 1, Trace stopped = 0

Name

Register No.

Remarks

Data Trace Group 1

SW00100

Latest record number

Name

Register No.

Remarks

I/O Error Count

SW00200

Number of I/O errors

Input Error Count

SW00201

Number of input errors

Input Error Address

SW00202

Latest input error address
(Register number of OWxxxx)

(For future use)

Output Error Count

SW00203

Number of output errors

Output Error Address

SW00204

Latest input error address
(Register number of OWxxxx)

(For future use)

Reserved by System

SW00205

(Not used.)

SW00206

SW00207