Parameters

6.3.1 Motion Fixed Parameter Details

6-10

14

Additional Function
Selections
(AFUNCSEL)

Set additional functions, such as the signal type used and signal functions.

Bit

0 to 1

Not used.

---

2

Limit Switch Signal Selection
(LIMITSEL)

Set whether to use OBC00IF or DI
signal (DEC signal of SGDH) as the
limit switch signal when returning to
the zero point.

0: Use OBC001F.
1: Use the DI signal (DEC signal

of SGDH).

When using OBC001F, the external
signal (DI signal input by the
LIO_01 or other Module) in the user
program must be connected (i.e.,
programmed) to OBC001F.

0

3 to 6

Not used.

---

7

Motion Command Code Selection
(MCMDSEL)

Set whether or not to use an
OWC020: Motion Command Code
when bit 2 of OWC000: Position
Control Mode is selected.

0: Not used.
1: Used.

1

8 to 11

Not used.

---

14

Bit

12 to 15

Deviation Error Abnormality Detec-
tion Value Coefficient
(EOV_MULTI)

The deviation error is detected using
the value of

EOV_MULTI

of the

deviation error detection value set-
ting (OWC00F).

• Setting range: 0 to 15

0

15

Not used.

---

16

Simulation Mode
Selection
(SIMULATE)

0 to 1

0: Normal operation mode
1: Simulation mode

0
(Normal opera-
tion)

17

Motion Controller
Function Selection
Flags
(SVFUNCSEL)

Set whether a function is enabled or disabled when a motion command is
used.

Bit

0 to 3

Reference Unit Selection
(CMD_UNIT)

Set the reference unit that is input.

0: pulse (electronic gear disabled)
1: mm
2: deg
3: inch

Set 0 to 3.
When a unit is selected, the mini-
mum unit that can be used as refer-
ence is determined by motion fixed
parameter No. 18: Number of Digits
Below the Decimal Point.

0
(pulse)

No.

Name

Description

Default

2

×