6.3 SVA Parameter Details
6-33
6
57
Encoder Position
at Shutdown
(Lower place)
OLC038
-2
31
to 2
31
-1
This parameter is used in the following two ways
and should be used with care.
1. Lower-place 2 Words of Encoder Position at
Shutdown
This parameter is valid when the motion fixed
parameter: Encoder Selection is set to absolute
encoder (= 1) and motion fixed parameter:
Axis Selection (bit 5 of the Motion Controller
Function Selection Flags) is set to an infinite
length axis ( = 1).
When bit 2 of OWC02D: ABS System Infinite
Length Position Control Data Load Request
turns ON, the data set at this parameter will be
treated as the lower-place two words of the
encoder position at shutdown.
2. Position Buffer Access Number
When bit 14 of OWC021: Position Buffer
Write or bit 15 of OWC021: Position Buffer
Read turns ON, the data set at this parameter
will be treated as the buffer number of the
position buffer. The setting range for this
parameter is 1 to 256 and it is not valid if set to
“0.” It is used when an OWC020: Motion
Command Code is used in Position Control
Mode.
0
SGDH Serial
Command
Command
Settings
OWC038
(Reserved for
system use)
Motion Command Control Flag
SGDH parameters are read/written when
(OBC021B)=1
1: Read data; 2: Write data
Note: Can be used only when motion command
code is enabled.
SGDH serial command cannot be used with the
following settings.
• The SERVOPACK Parameters Window is
opened using CP-717 Programming Device.
• A Digital Operator is connected to the SERVO-
PACK.
0
SGDH Serial
Command
Address Setting
OWC039
(Reserved for
system use)
Motion Command Control Flag
Sets the SGDH parameter read/write address when
the motion command control flag (OWC021B)=1.
Note: Can be used only when motion command
code is enabled.
0
No.
Name
Register
Number
Bit Name
Description
Default