5.5.2 Typical Main Circuit Wiring

5-34

5.5.2 Typical Main Circuit Wiring

The following diagram shows a typical wiring example.

„

Designing a Power ON Sequence

Note the following points when designing the power ON sequence.

• Design the power ON sequence so that power is turned OFF when a servo alarm signal is

output. (See the circuit figure above.)

• Hold the power ON button for at least two seconds. The SERVOPACK will output a

servo alarm signal for two seconds or less when power is turned ON. This is required in
order to initialize the SERVOPACK.

1MCCB: Molded-case circuit breaker (for
the inverter)

1Ry: Relay

FIL: Noise filter

1PL: Indicator lamp

1MC: Magnetic Contactor

1SUP: Surge suppressor

1D: Flywheel diode

M

FIL

1Ry

1Ry

1MC

1MC

1SUP

1MC

L1

L2

L3

L1C

L2C

SGDM-□□AD

U

V

W

A

B

C

D

PG

CN1

31

+24V

ALM

ALM

-SG

32

1D 024V

1Ry

1MCCB

R

S T

1PL

SERVOPACK

For servo alarm display

Main power

supply ON

Main power

supply OFF

Power supply

2.0 s max.

Servo alarm (ALM)