6.4.7 Sequence-related Parameters

6-66

6.4.7 Sequence-related Parameters

Table 6.9 Sequence-related Parameter Table

Parameter No. Digit

Name (Setting

Range)

Details

Default

Control

Modes

Pn500
Positioning
Completed Width

Reference unit
0 to 250

Do not use this parameter when using an MP940.

7

Position

Pn501
Zero Clamp Level

r/min
0 to 10000

The zero clamp function is used for systems where the host con-
troller does not form a position loop for the speed reference input.
In other words, this function is used to stop and lock the servomo-
tor even when the input voltage of speed reference INVRF is not 0
V. An internal position loop is temporarily formed to clamp the ser-
vomotor within one pulse when the zero clamp function is turned
ON. Even if the servomotor is forcibly rotated by external force, it
will still return to the zero clamp position.
Zero Clamp Function
This mode allows the zero clamp function to be set when the servo-
motor stops. The speed reference is input from INVRF.
ZCLAMP(OBC0015) is used to turn the zero clamp function ON
and OFF.

ZCLAMP=0: Turns the zero clamp function OFF.
ZCLAMP=1: Turns the zero clamp function ON.

Zero clamp is performed when the following two conditions are
satisfied:
Condition 1: ZCLAMP is ON.
Condition 2: Speed reference is below the setting at Pn501.
Set the motor speed at which zero clamp is performed if zero clamp
speed control is selected. Even if this value is set higher than the
maximum speed of the servomotor, the maximum speed will be
used.
Zero Clamp Conditions
Zero clamp is performed when all the following conditions are sat-
isfied:

• ZCLAMP (OBC0015) is ON (0 V).
• Motor rotation speed is below this setting.

10

Speed

ピタッ!

ZCLANP

OBC0015)

INVRF

BAT

RDY
RUN
ALM
BAT
PRT1

6
5
4
3
2
1

NO

PRT2

RUN
INIT
TEST
FLASH
PP
COPY

PORT1

PORT2

POWER

+24V

GND
FG

LED

I/O

TX
RX

1

2

M
E
C
H
A
T
R
O
L
I
N
K

MP940

MP940

A speed reference below the

Pn501 setting is ignored.

Speed reference

Stops

precisely.

Speed

Preset value for zero

clamping

V-REF speed reference

Time

ZCLAMP input

Zero clamp is performed.

Open

(OFF)

Closed

(ON)