5.8 System Startup

5-65

5

„

Default Settings for SGDH SERVOPACK Parameters

1. Click SERVOPACK in the SVA Definitions Window. The SERVOPACK Parameter Set-

tings Window will be displayed.

Select

Edit (E)

and then

Default Set (R)

from the menus.

2. The SVA Definition Message Box will be displayed. Click the

Yes (Y)

Button to set the

default values.

3. Save the SERVOPACK parameters.

Click

Save

on the toolbar. The Save SVA Configuration Message Box will be displayed.

Click the

Yes (Y)

Button.