beautypg.com

Grass Valley Kaleido-X v.7.80 User Manual

Page 539

background image

531

Kaleido-X

User’s Manual

• Download the database from the multiviewer to your local workspace

(see

Importing a Database

on page 79).

Configuring Power Supply Redundancy on a Kaleido-X16

Power supply redundancy is an option on the Kaleido-X16, which can ship with a single
PSU. In order to avoid having the system dashboard display unnecessary alarms, there is a
check box in XAdmin to indicate the presence of the second PSU. By default, this option is
selected (both PSUs are monitored). Removing the check mark will stop the monitoring of
alarms for PSU B (its status is set to disabled, and therefore will not appear on the
dashboard).

Location of Slot A and Slot B in the front of the Kaleido-X16 frame

To configure the PSU B Installed option in XAdmin

1 Open XAdmin. See

Opening XAdmin

on page 507.

The XAdmin Status and Options page appears.

2 In the SYSTEM heading row, click the Expand details arrow (

).

A list of system details and statuses appears below the System heading row.

3 At the top of the list, select or clear PSU B Installed, as required.

IMPORTANT

Upgrading or reinstalling the Kaleido-X software removes all additional fonts
you may have uploaded to the multiviewer. In such case, you will need to
repeat this procedure.

Slot A

Slot B

PSU A removed

from Slot A

This manual is related to the following products: