Administration and Servicing
Dashboard Messages
Upgrade dashboard messages
Blower 4 (replace whole
module if in error)
Blower 4 is running too low or is broken.
x
Card temperature critical
Card is overheating, which might result in
decreased system performance (e.g.,
green dots, flickering, card not starting).
You should halt operations until the
overheating problem is resolved.
x
x
x
Card temperature high
Temperature warning, which indicates
that the card is warmer than normal and
that you should verify cooling and
ventilation (e.g., check for anything
obstructing the ventilation openings).
x
x
x
Critical voltage upper limit
reached
One of the voltages is above the critical
threshold.
x
Critical voltage lower limit
reached
One of the voltages is below the critical
threshold.
x
Critical current upper limit
reached
Current or power is above the critical
threshold.
x
FPGA fan failed
FPGA fan failed
x
Firmware status
Tells whether firmware is running
properly on the card.
x
HDMI 0 power failed
HDMI output for first head has a power
failure.
x
HDMI 1 power failed
HDMI output for second head has a
power failure.
x
Message
Description
7RU 4RU
Error during firmware
upgrade. Firmware
upgrade cannot proceed
until legacy KXO (<3.00)
are removed from
frame B.
This message will appear on an expansion frame with
expansion enabled and with cards in Frame B running
software or firmware older than version 3.00. To
upgrade these cards, transfer them to Frame A.
x
Error during firmware
upgrade. Card presence
from frame B could not be
verified.
This message will appear as a side effect of the
presence of cards in Frame B running a version older
than version 3.00. The upgrade will not be permitted
on any card in the frame until these cards are removed
from Frame B. To upgrade these cards, transfer them
to Frame A.
x
Message
Description
7RU 4RU X16
KMV KMX