beautypg.com

Grass Valley Kaleido-X v.7.80 User Manual

Page 204

background image

196

Logical Sources

Creating and Configuring Logical Sources

• If you wish to exclude alarms in this level from the global alarm calculation, then

clear the Include in global alarm check box.

• To rank this level’s contribution to your system’s global alarms, click the Global

alarm contribution box, and then select the appropriate value from the list.

Passthrough: This is the default value. Alarms in this level will pass their status

unaltered to the global alarms.

Critical, Major, Minor, Disabled: It is possible to override the error status of

alarms when they are triggered. This is useful when, for example, a device is
only able to report a status of either normal or error, but you want the error
condition to be considered as minor in the global alarm calculation.

Invert: Alarms in this level will pass the opposite of their status to the global

alarms. This can be used, for example, to report alarms from GPI inputs, or to
handle cases where an error is expected, and not seeing an error is a sign that
something probably went wrong. The table below describes the result of
inverting sub-alarms:

Alarm status

Inverted contribution

NORMAL

ERROR

MINOR

NORMAL

MAJOR

NORMAL

CRITICAL

NORMAL

NON-EXISTENT

NON-EXISTENT

PENDING

PENDING

Selected alarm level

This manual is related to the following products: