Adding a timer monitor to a layout – Grass Valley Kaleido-X v.7.80 User Manual
Page 291

283
Kaleido-X
User’s Manual
10 Click Save to save your new timer and close the Timer Editor window.
11 Under the Channels/Sources tab, create a new logical source to associate with the
timer, and name it.
12 Click a cell in the time code level of the new logical source, and drag the timer you wish
to assign to this logical source from the filtered System list that appears in the Tools
pane, to the selected cell in the sources table.
13 Click Save.
Adding a Timer Monitor to a Layout
To create a timer monitor
1 In XEdit, open a layout and click the Timer button
.
2 Click and drag to draw a timer monitor on the layout.
• If the selected time code reference does not include time zone
information, or you chose to bind the timer to the multiviewer’s
internal clock, then the multiviewer's system time will apply.
• In the case of a Kaleido-X or Kaleido-X16 multiviewer model,
make sure the time zone settings are the same, on the
multiviewer, and on the PC or laptop that has XEdit.
• In the case of a KMV-3901/3911, when you save or export the
timer to the multiviewer, XEdit automatically converts the
start time you specified to UTC, based on your computer’s time
zone settings.
Note:
In the case of a Kaleido-X or Kaleido-X16 multiviewer
model, the system's time zone is configured in XAdmin. In the case
of a KMV-3901/3911, time is always based on UTC. On a Windows
PC or laptop, the time zone is configured in the Date and Time
control panel.