Section 25 Electrical Characteristics

Rev. 4.00 Sep. 14, 2005 Page 908 of 982

REJ09B0023-0400

25.1.1 Power-On

Sequence

Supply the power so that VccQ (3.3-V system) and Vcc (1.8-V system) are supplied
simultaneously or Vcc is supplied after VccQ is supplied.

Recommended values for the power-on procedure are shown below.

V

CC

Q (min.) voltage

V

CC

Q: 3.3 V-system power supply

V

CC

: 1.8 V-system power supply

V

CC

(min.) voltage

t

pwu

t

unc

GND

V

CC

/2 level voltage

The time at which VccQ
reaches V

CC

Q (min.)

The time at which Vcc
reaches V

CC

(min.)

Unsettling opration

Normal operation

Operation stopped

Clock starts oscillation

Oscillation settling time (10 ms)

Power-on reset released and then
normal operation started

t

pwd

Figure 25.1 Power-On Sequence