beautypg.com

Renesas SH7641 User Manual

Page 713

background image

Section 18 Multi-Function Timer Pulse Unit (MTU)

Rev. 4.00 Sep. 14, 2005 Page 663 of 982

REJ09B0023-0400

(20) Operation when Error Occurs during Phase Counting Mode Operation, and Operation

is Restarted in Phase Counting Mode

Figure 18.104 shows an explanatory diagram of the case where an error occurs in phase counting
mode and operation is restarted in phase counting mode after re-setting.

1

RESET

2

TMDR
(PCM)

3

TIOR
(1 init

0 out)

5

TSTR

(1)

4

PFC

(MTU)

6

Match

7

Error

occurs

8

PFC

(PORT)

9

TSTR

(0)

10

TMDR
(PCM)

11

TIOR
(1 init

0 out)

12

PFC

(MTU)

13

TSTR

(1)

High-Z

High-Z

MTU module

output

TIOC*A

TIOC*B

Port output

TIOC*A/PTE[n]

TIOC*B/PTE[n]

n = 0 to 15

Figure 18.104 Error Occurrence in Phase Counting Mode,

Recovery in Phase Counting Mode

1 to 9 are the same as in figure 18.101.

10. Not necessary when restarting in phase counting mode.

11. Initialize the pins with TIOR.

12. Set MTU output with the PFC.

13. Operation is restarted by TSTR.