Section 21 A/D Converter

Rev. 4.00 Sep. 14, 2005 Page 806 of 982

REJ09B0023-0400

Channel 0 (AN0)

operating

ADIE

ADST

ADF

Channel 1 (AN1)

operating

Channel 2 (AN2)

operating

Channel 3 (AN3)

operating

ADDRA

ADDRB

ADDRC

ADDRD

Waiting

Waiting

Waiting

Waiting

Waiting

Waiting

A/D conversion starts

Set*

Set*

Set*

Clear*

Clear*

A/D conversion result 1

A/D conversion result 2

Read result

Read result

A/D conversion 1

A/D conversion result 2

Note: * Vertical arrows (

) indicate instruction execution by software.

Figure 21.2 Example of A/D Converter Operation (Single Mode, Channel 1 Selected)

21.3.2 Multi

Mode

Multi mode should be selected when performing A/D conversions on one or more channels. When
the ADST bit is set to 1 by software, A/D conversion starts on the first channel in the group (A/D0
when AN0, A/D1 when AN4). When two or more channels are selected, after conversion of the
first channel ends, conversion of the second channel (AN1 or AN5) starts immediately. When A/D
conversions end on the selected channels, the ADST bit is cleared to 0. The conversion results are
transferred for storage into the A/D data registers corresponding to the channels.

When the mode or analog input channel selection must be changed during A/D conversion, to
prevent incorrect operation, first clear the ADST bit to 0 to halt A/D conversion. After making the
necessary changes, set the ADST bit to 1. A/D conversion will start again from the first channel in
the group. The ADST bit can be set at the same time as the mode or channel selection is changed.