Section 18 Multi-Function Timer Pulse Unit (MTU)

Rev. 4.00 Sep. 14, 2005 Page 551 of 982

REJ09B0023-0400

Bit Bit

Name

Initial
value R/W

Description

4 TCFV

0 R/(W) Overflow

Flag

Status flag that indicates that TCNT overflow has
occurred. Only 0 can be written, for flag clearing.

[Setting conditions]

• When the TCNT value overflows (changes from

H'FFFF to H'0000 )

• In channel 4, when TCNT_4 is underflowed (H'0001

→ H'0000) in complementary PWM mode.

[Clearing condition]

• When 0 is written to TCFV after reading TCFV = 1

3

TGFD

0

R/(W) Input Capture/Output Compare Flag D

Status flag that indicates the occurrence of TGRD input
capture or compare match in channels 0, 3, and 4. Only
0 can be written, for flag clearing. In channels 1 and 2,
bit 3 is reserved. It is always read as 0, and should only
be written with 0.

[Setting conditions]

• When TCNT = TGRD and TGRD is functioning as

output compare register

• When TCNT value is transferred to TGRD by input

capture signal and TGRD is functioning as input

capture register

[Clearing condition]

• When 0 is written to TGFD after reading TGFD = 1