Section 18 Multi-Function Timer Pulse Unit (MTU)

Rev. 4.00 Sep. 14, 2005 Page 536 of 982

REJ09B0023-0400

Table 18.14 TIORH_3 (Channel 3)

Description

Bit 7
IOB3

Bit 6
IOB2

Bit 5
IOB1

Bit 4
IOB0

TGRB_3
Function


TIOC3B Pin Function

0 0 0 0

Output

hold*

1

Output
compare
register

Initial output is 0

0 output at compare match

1

0

Initial output is 0

1 output at compare match

1

Initial output is 0

Toggle output at compare match

1 0 0

Output

hold*

1

Initial output is 1

0 output at compare match

1

0

Initial output is 1

1 output at compare match

1

Initial output is 1

Toggle output at compare match

1

X

0

0

Input capture at rising edge

1

Input capture at falling edge

1 X

Input capture
register

Input capture at both edges

[Legend]

X: Don't care

Note: * The low level output is retained until TIOR contents is specified after a power-on reset

and entering standby mode.