beautypg.com

Renesas SH7641 User Manual

Page 712

background image

Section 18 Multi-Function Timer Pulse Unit (MTU)

Rev. 4.00 Sep. 14, 2005 Page 662 of 982

REJ09B0023-0400

(19) Operation when Error Occurs during Phase Counting Mode Operation, and Operation

is Restarted in PWM Mode 2

Figure 18.103 shows an explanatory diagram of the case where an error occurs in phase counting
mode and operation is restarted in PWM mode 2 after re-setting.

1

RESET

2

TMDR
(PCM)

3

TIOR
(1 init

0 out)

5

TSTR

(1)

4

PFC

(MTU)

6

Match

7

Error

occurs

8

PFC

(PORT)

9

TSTR

(0)

10

TMDR

(PWM2)

11

TIOR
(1 init

0 out)

12

PFC

(MTU)

13

TSTR

(1)

High-Z

High-Z

• Not initialized (cycle register)

MTU module

output

TIOC*A

TIOC*B

Port output

TIOC*A/PTE[n]

TIOC*B/PTE[n]

n = 0 to 15

Figure 18.103 Error Occurrence in Phase Counting Mode, Recovery in PWM Mode 2

1 to 9 are the same as in figure 18.101.

10. Set PWM mode 2.

11. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized.)

12. Set MTU output with the PFC.

13. Operation is restarted by TSTR.