beautypg.com

Renesas SH7641 User Manual

Page 705

background image

Section 18 Multi-Function Timer Pulse Unit (MTU)

Rev. 4.00 Sep. 14, 2005 Page 655 of 982

REJ09B0023-0400

(12) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is

Restarted in Reset-Synchronous PWM Mode

Figure 18.96 shows an explanatory diagram of the case where an error occurs in PWM mode 1
and operation is restarted in reset-synchronous PWM mode after re-setting.

1

RESET

2

TMDR

(PWM1)

3

TOER

(1)

5

PFC

(MTU)

4

TIOR
(1 init

0 out)

6

TSTR

(1)

7

Match

8

Error

occurs

9

PFC

(PORT)

10

TSTR

(0)

11

TMDR

(normal)

12

TIOR
(0 init

0 out)

13

TIOR

(disabled)

14

TOER

(0)

15

TOCR

16

TMDR

(RPWM)

17

TOER

(1)

18

PFC

(MTU)

19

TSTR

(1)

• Not initialized (TIOC3B)

• Not initialized (TIOC3D)

High-Z

High-Z

High-Z

MTU module

output

TIOC3A

TIOC3B

TIOC3D

Port output

TIOC3B/PTE[6]

TIOC3A/PTE[7]

TIOC3D/PTE[4]

Figure 18.96 Error Occurrence in PWM Mode 1,

Recovery in Reset-Synchronous PWM Mode

1 to 14 are the same as in figure 18.95.

15. Select the reset-synchronous PWM output level and cyclic output enabling/disabling with

TOCR.

16. Set reset-synchronous PWM.

17. Enable channel 3 and 4 output with TOER.

18. Set MTU output with the PFC.

19. Operation is restarted by TSTR.

This manual is related to the following products: