Section 18 Multi-Function Timer Pulse Unit (MTU)

Rev. 4.00 Sep. 14, 2005 Page 619 of 982

REJ09B0023-0400

18.6 Operation

Timing

18.6.1 Input/Output

Timing

TCNT Count Timing: Figure 18.54 shows TCNT count timing in internal clock operation, and
figure 18.55 shows TCNT count timing in external clock operation (normal mode), and figure
18.56 shows TCNT count timing in external clock operation (phase counting mode).

TCNT

TCNT input
clock

Internal clock

P

φ

N-1

N

N+1

N+2

Falling edge

Rising edge

Figure 18.54 Count Timing in Internal Clock Operation

TCNT

TCNT input
clock

External clock

P

φ

N-1

N

N+1

N+2

Falling edge

Rising edge

Falling edge

Figure 18.55 Count Timing in External Clock Operation