Section 18 Multi-Function Timer Pulse Unit (MTU)

Rev. 4.00 Sep. 14, 2005 Page 621 of 982

REJ09B0023-0400

P

φ

TCNT input
clock

TCNT

N

N+1

TGR

Compare
match signal

TIOC pin

N

Figure 18.58 Output Compare Output Timing

(Complementary PWM Mode/Reset Synchronous PWM Mode)

Input Capture Signal Timing: Figure 18.59 shows input capture signal timing.

TCNT

Input capture
input

N

N+1

N+2

N

N+2

TGR

Input capture
signal

P

φ

Figure 18.59 Input Capture Input Signal Timing