beautypg.com

MTS Multipurpose Elite User Manual

Page 433

background image

Description

Number

DAQ List: Data Acquisition 1

Trigger 1: Timed

Buffer Size: 1 count

Save data to variables: Yes, automatically map variables (signal-dependent variables)

Configure the Set Span and Setpoint activity:

5

Maintain command: Disabled

Monitor: Continuous

Channel: Axial

Control Mode: Displacement

Span; Setpoint: Defined as calculated variable values as shown below.

Allow activity to execute when test is stopped: Enabled

Configure the State Change Detection activity:

6

Program state change: Stopping

Note:

If the test is stopped, the Set Span and Setpoint activities continue since the Allow
activity to execute when the test is stopped
check box is enabled.

Select the State Change Detection as a Terminal Path (see activity number 3).

Below the Parallel Paths activity, add a serial Set Span and Setpoint activity configured for
maintaining command. Property settings:

7

Maintain command to prevent movement: Enabled

Channel: Axial

Control Mode: Displacement

Span: 100%

Setpoint: 0 (units)

Allow activity to execute when test is stopped: Enabled

Add a Ramp activity to ramp to zero. Property settings:

8

Timing Type: Time

MTS TestSuite | 433

Test Activities