Description
Number
•
DAQ List: Data Acquisition 1
•
Trigger 1: Timed
•
Buffer Size: 1 count
•
Save data to variables: Yes, automatically map variables (signal-dependent variables)
Configure the Set Span and Setpoint activity:
5
•
Maintain command: Disabled
•
Monitor: Continuous
•
Channel: Axial
•
Control Mode: Displacement
•
Span; Setpoint: Defined as calculated variable values as shown below.
•
Allow activity to execute when test is stopped: Enabled
Configure the State Change Detection activity:
6
•
Program state change: Stopping
Note:
If the test is stopped, the Set Span and Setpoint activities continue since the Allow
activity to execute when the test is stopped check box is enabled.
•
Select the State Change Detection as a Terminal Path (see activity number 3).
Below the Parallel Paths activity, add a serial Set Span and Setpoint activity configured for
maintaining command. Property settings:
7
•
Maintain command to prevent movement: Enabled
•
Channel: Axial
•
Control Mode: Displacement
•
Span: 100%
•
Setpoint: 0 (units)
•
Allow activity to execute when test is stopped: Enabled
Add a Ramp activity to ramp to zero. Property settings:
8
•
Timing Type: Time
MTS TestSuite | 433
Test Activities