Task
Reference

Timed DAQ Trigger Properties

(p. 144)

Peak Valley DAQ Trigger Properties

(p. 147)

Timed DAQ Triggering Overview

Timed data acquisition records the values of selected signals at a user-defined frequency (sample rate)
for a specified duration.

Timed DAQ Triggering

For More Information

Task
Reference

Timed DAQ Trigger Properties

(p. 144)

Peak Valley DAQ Trigger Properties

(p. 147)

Timed DAQ Trigger Properties

DAQ Timed Trigger Properties Window

Sample Selection

Select the method used to determine when data is acquired.

Time Between Points - Provides a convenient list of time units (ms, sec, minute, hour, day) that allow
you to define when data is acquired.

The time between points setting must be a multiple of the system period:

— If you are connected to a controller, the time that you enter is automatically adjusted to be the closest

multiple of the system period.

— If you are not connected to a controller, you can enter any value; however, when you do connect to

a controller, the application checks the system rate and automatically adjusts the time to the closest
multiple of the system period.

144 | MTS TestSuite

Data Acquisition (DAQ)