Clear-Com Eclipse-Omega User Manual
Page 423
Clear-Com
Eclipse Configuration Software Instruction Manual
1 2 - 4 1
In this event it is possible that some panels will be left with the new
firmware if they completed updating before the new download from
ECS started whilst others will still have the previous firmware. In this
case the panel firmware will have to be downloaded to the matrix again
and the panels allowed to update.
Note: The panels always update with a new firmware download
regardless of their current firmware version; there is no
version checking.
The V-Series firmware images downloaded are held in system RAM;
the images are retained on NIDS and RED resets, a power cycle or
BLACK reset will clear the image. Note that only one V-Series
firmware image may be downloaded at any one time.