Applies to, Linking options, Remote system – Clear-Com Eclipse-Omega User Manual
Page 148: Applies to: -38, Linking options -38, Remote system -38
Clear-Com
Eclipse Configuration Software Instruction Manual
5 - 3 8
2. Click the drop-down arrow to turn the Audio Presence Tally feature
on or off.
The operator can speak into a panel’s microphone and adjust the
threshold value so that the audio presence light just goes out when the
operator is not speaking, or input a tone into the interface input and
adjust the threshold value.
Applies to:
On V12LD, V24LD, V12PD, V24PD, V12LDD, Concert, ICS 2003, ICS
102, PD4224, i-Station, CCI-22, ICS 1008, ICS 1016, ICS 52, ICS 62,
ICS 92, PD4212, PD4215, PD4226 panels, Direct, AES Mono, Panel
Aux, FOR-22 and Telephone devices.
Note: This feature is not available on IP panels.
LINKING OPTIONS
Remote System
Specifies the remote system the trunk device is connected to. This is
configured in ‘System’ and is displayed in Advanced Settings for
information only; it cannot be set using Advanced Settings.
Applies to:
Only used on Trunk devices.