Latch disable, Mute listen with talk, Prevent reply signalization – Clear-Com Eclipse-Omega User Manual
Page 134: Station connected tally, Applies to, Ip panel settings, Audio codec, Network connection, Latch disable -24, Mute listen with talk -24
Clear-Com
Eclipse Configuration Software Instruction Manual
5 - 2 4
Latch Disable
This function prevents talks to the port from latching. If a
latch-disabled port is assigned to a talk key, the key can only talk to the
port for as long as the operator physically holds down the key. A
latch-disabled port can be included in a fixed group or party line
without automatically latch disabling the entire fixed group or party line.
Mute Listen With Talk
When set to true mutes listens to selected port on calling panel and
panels nearby to calling panel.
Note: Panel Aux only.
Prevent Reply Signalization
Prevents key signalization for the calling panel appearing on the
answerback (reply key).
Station Connected Tally
This allows the system to set a tally (flashing LED) on a panel
indicating that the corresponding panel is connected to the system.
The default is disabled.
This is normally used on remotely connected panels where the panel
to matrix comms may suffer from an occasional loss of service.
Note: Not available for CCI-22, AES Mono, Panel Aux and Direct
(no keys).
Applies to:
On V-Series, Concert, ICS 2003, ICS 102, PD4224, i-Station, ICS
1008, ICS 1016, ICS 52, ICS 62, ICS 92, PD4212, PD4215, PD4226,
Direct, AES Mono, Panel Aux, FOR-22 and Telephone devices.
IP PANEL SETTINGS
Audio Codec
Allows the codec to be selected for IP connections. Currently only the
G.722 Codec is available. This is the default.
Network Connection
Selects the network connection type for an IP panel. Select from LAN
(high speed), WAN (intermediate) or Internet (low speed) from a
drop-down menu. The default ins LAN.