beautypg.com

Online limitations, Online limitations -7 – Clear-Com Eclipse-Omega User Manual

Page 349

background image

Clear-Com
Eclipse Configuration Software Instruction Manual

9 - 7

ONLINE LIMITATIONS

Online mode provides much of the functionality of Panel Programming
but it cannot be used to create new entities; this must be done in ECS.
Specifically Online mode cannot:

• Create or edit a Party Line.

• Create or edit a Fixed Group.

• Create or edit a Control.

• Create a Talk and Forced Listen key.

• Create the first remote key to a Fixed Group.

• Create the first remote key to a Party Line.

• Create the first remote key to a Control.

• Create a stacked key.

Also, as noted previously Online cannot assign a label that refers to a
remote system unless it is already present in the current map. In order
for such a label to be present in a configuration it must have been
assigned at least once and then downloaded as part of a map. In this
way it will be recognized by the matrix if it is assigned in Online mode.