beautypg.com

Talk label, Listen label, Description – Clear-Com Eclipse-Omega User Manual

Page 159: Card properties, Card position, Clock recovery, Figure 5-20 e1 trunk card properties -49

background image

Clear-Com
Eclipse Configuration Software Instruction Manual

5 - 4 9

Talk Label

Talk label for the E1 trunk used to assign the trunk line in ‘My
Systems’.

Listen Label

Listen label for the E1 trunk used to assign the trunk line in ‘My
Systems’.

Description

Option port description up to 255 characters long.

Card Properties

For an E-QUE card in E1 Trunk mode the Clock Recovery mode and
Codec should be set by clicking on the ‘Card Properties’ link in the
lower right of the hardware display. This will display the Clock
Recovery and Codec setup.

Figure 5-20: E1 Trunk Card Properties

Card Position

The slot number of the selected card is displayed.

Clock Recovery

The data clock may be generated by the E-QUE card (Local
Generated) or taken from the E1 line. Normally the card should be set
to ‘Line Recovery’ for connection to a third party device or E1 network.
For other devices the clock source will need to be determined before
configuration. Select the correct configuration by clicking on the
appropriate radio button.

If connecting two Eclipse matrices back to back using E1:

• An E1 or T1 crossover cable is required.

• One E-QUE card should be set to ‘Local Generated’ clock and the

other to ‘Line Recovery’ clock.