E1 direct, Port function, Talk label – Clear-Com Eclipse-Omega User Manual
Page 156: Listen label, Description, E1 direct -46
Clear-Com
Eclipse Configuration Software Instruction Manual
5 - 4 6
Figure 5-15: E-Que Card Selection
E-QUE cards can be configured as E1 Direct, E1 Trunk, T1 Trunk,
Antenna or Splitter cards.
E-QUE cards should be fitted to the rightmost free slots in the Median
or Omega matrices (furthest from the config cards). A maximum of
four of any combination of E-QUE, IVC-32 and LMC-64 cards can be
fitted to an Omega or Median matrix regardless of the E-QUE card
mode. If the user attempts to add more than four E-QUE, IVC-32 and
LMC-64 cards in total to the matrix an error message is displayed
(Figure 5-16).
Figure 5-16: Configuring Too Many E-QUE/IVC-32 Cards
E1 Direct
This action automatically adds an E-QUE card configured for 60 direct
ports using E1 protocol. Each E1 port can be used as an E1
communication line to another E1 device.
Port Function
This is always set to ‘E1 Direct’.
Talk Label
Talk label for the E1 direct port used to assign the port to a talk path.
Listen Label
Listen label for the E1 direct port used to assign the port to a listen
path.
Description