Eclipse Configuration Software Instruction Manual

5 - 6 6

Figure 5-39: LMC-64 IP Parameters

General

Default ports used by the Eclipse system are 6001 for IP Panel
communications, 42001 for ECS communications and 1300 for the
matrix event log. Ports 42001 and 1300 are used by the UDP/
protocol. Eclipse system administrators are advised to check with
network administrators or IT that these default ports may be used
without causing a conflict with any other application on the network.

Each LMC-64 card requires a static IP address. It is recommended
that these addresses are issued by IT or the Network Administrator to
avoid conflicts with any other system on the network and are not part
of the DHCP dynamically assigned range.

IP Port

Sets the port number to be used by the LMC-64 card when
communicating over IP. This parameter should not normally be
changed from the default value. Eclipse system administrators are
advised to check with network administrators or IT that the default port
may be used without causing a conflict with any other application on
the network.

If the IP port number is changed ports 42001 and 1300 should not be
used as these ports are already used by ECS. The Eclipse system
administrator should check with the network administrator or IT to
obtain a port number to use.

IP Address Assignment

Manually enter the IP address, subnet mask and default gateway for
the LMC-64 card.