beautypg.com

Menu options, Beltpack menu, Soft mode options – Clear-Com Eclipse-Omega User Manual

Page 227: Default assign as talk and forced listen, Enable assignment as a listen, Enable assignment as talk, Protect port from assignment, Beltpack programming, Menu options -117, Beltpack menu -117

background image

Clear-Com
Eclipse Configuration Software Instruction Manual

5 - 1 1 7

MENU OPTIONS

Beltpack Menu

The setting determines the level of access the beltpack user has to the
beltpack menus to alter settings. The four settings are:

• Advanced - full access to all menu options and settings.

• Normal - beltpack microphone type and headphone limiter setting

are locked, all other options and settings are available.

• Basic - all beltpack options and settings are locked except

contrast, master volume, key lock, tap latch, page lock and
information screens.

• None - all menus and settings are locked and cannot be viewed.

SOFT MODE OPTIONS

Default Assign as Talk and Forced Listen.

When true the default for a key assigned to this label is Talk and
Forced Listen.

Enable Assignment as a Listen

Allow the port to be assigned locally via Soft Mode as listen key by
another panel.

Enable Assignment as Talk

Allow the port to be assigned locally via Soft Mode as talk key by
another panel.

Protect Port from Assignment

Prevents this port from being locally assigned by another panel in soft
mode.

BELTPACK PROGRAMMING

Beltpack programming (assigning labels to keys, setting beltpack
operating parameters etc is now carried out in Panel Programming
treating the beltpack as a panel where labels can be dragged and
dropped onto keys in the same way as panels.

To program a beltpack select ‘Panel programming’ from the
Configuration menu and select the required beltpack from the
drop-down list of panels at the top of the window. The beltpack mimic
will be displayed.