beautypg.com

Clear-Com WP-6 User Manual

Wp-6 installation wiring, Wiring detail

background image

Filename: 810051MB.DWG

WP-6 INSTALLATION WIRING

REAR VIEW

WIRING DETAIL

SHIELD (COMMON)

EARTH COMMON

ONLY IF CONDUIT

IS USED

(

(

MULTI-PAIR

INDIVIDUALLY

CONDUIT

+30V

CH A AUDIO

PIN 1

PIN 3

PIN 4

PIN 2

XLR PIN ASSIGNMENTS

RED

YEL/WHT

YEL

BLK

+30V

CH B AUDIO

SHIELD

(

TIE 2 SHIELDS

TO COMMON

(

SHIELDED CABLE

IN SEPARATE SHIELDED PAIRS.

CHANNELS 'A' AND 'B' ARE TO BE

IMPORTANT

CIRCUIT GROUND

CH B AUDIO

CH A AUDIO

6-PIN XLR

CONNECTOR

POWER

CH. A AUDIO

DRAIN WIRE GND**

CH. B AUDIO

GND*

DRAIN WIRE GND**

* = SPARE WIRE USED

** = IF THE SHIELDS FROM

INDIVIDUAL PAIRS ARE

THEY MUST ALSO BE

BROUGHT OUT SEPARATELY,

FOR GND

CONNECTED TO PIN 1.

3 PIN XLR CONNECTORS

5

4

3

6

1

2

2

3

1

1

3

2

2-Channel

Main Station

A

B

intercom systems

R