Clear-Com Eclipse-Omega User Manual
Page 124
Clear-Com
Eclipse Configuration Software Instruction Manual
5 - 1 4
• ICS-21 - The Eclipse Configuration Software (ECS) software does
not directly support the ICS-21 speaker panel. In order to configure
an ICS-21 panel the port is configured to drive an ICS-1008 panel
with 14 keys (7 pairs of buttons). The ICS-21 channel is mapped
onto the ICS-1008 keys starting from the left. Only the leftmost pair
of keys on the ICS-1008 can be used to program the ICS-21; any
other keys on the ICS-1008 will have no effect. There must be a
corresponding listen key on the top row to the talk key on the bottom
row of the ICS-1008 configuration for the ICS-21 panel to work
correctly. If a talk key only is configured on the ICS-1008 in ECS the
Talk key on the ICS-21 will not latch. Please refer to notes on
ICS-21/22/24 support at the end of this section.
• ICS-22 - The Eclipse Configuration Software (ECS) software does
not directly support the ICS-22 speaker panel. In order to configure
an ICS-22 panel the port is configured to drive an ICS-1008 panel
with 14 keys (7 pairs of buttons). The two ICS-22 selectors are
mapped onto the ICS-1008 keys starting from the left. Only the
leftmost two pairs of keys on the ICS-1008 can be used to program
the ICS-22; any other keys on the ICS-1008 will have no effect.
There must be a corresponding listen key on the top row to the talk
key on the bottom row of the ICS-1008 configuration for the ICS-22
panel to work correctly. If a talk key only is configured on the
ICS-1008 in ECS the Talk key on the ICS-22 will not latch. Please
refer to notes on ICS-21/22/24 support at the end of this section.
• ICS-24 - The Eclipse Configuration Software (ECS) software does
not directly support the ICS-24 headset panel. In order to configure
an ICS-24 panel the port is configured to drive an ICS-1008 panel
with 14 keys (7 pairs of buttons). The ICS-24 channels are mapped
onto the ICS-1008 keys starting from the left. Only the leftmost four
pairs of keys on the ICS-1008 can be used to program the ICS-24;
any other keys on the ICS-1008 will have no effect. There must be a
corresponding listen key on the top row to the talk key on the bottom
row of the ICS-1008 configuration for the ICS-24 panel to work
correctly. If a talk key only is configured on the ICS-1008 in ECS the
Talk key on the ICS-24 will not latch. Please refer to notes on
ICS-21/22/24 support at the end of this section.
• Danner Cassette -The Eclipse Configuration Software (ECS)
software does not directly support the Danner Cassette panel. In
order to configure a Danner Cassette panel containing two units of 8
keys each, the port connected to the Danner Cassette is configured
as a PD4224E panel in ECS.