System configuration limits, Online configuration, Matrix hardware setup – Clear-Com Eclipse-Omega User Manual
Page 115: System configuration limits -5, Online configuration -5, Matrix hardware setup -5
Clear-Com
Eclipse Configuration Software Instruction Manual
5 - 5
SYSTEM CONFIGURATION LIMITS
The Eclipse matrix system places certain limits on the numbers of
non-hardware configuration items such as fixed groups, stacked keys,
party lines and controls. These limits are:
• The maximum number of party lines that can be configured is 198
with a maximum of 99 members in each.
• The maximum number of fixed groups that can be configured is 100.
• The maximum number of stacked keys that can be allocated is 1024
less the number of fixed groups. For example if 100 fixed groups
have been allocated in ECS up to 924 stacked keys an be
configured (1024 - 100).
• The maximum number of controls and routes combined is 437. For
example if 50 routes are configured the maximum number of
controls that can be created will be 387 (437 - 50).
• The maximum number of speed dials is 100.
• The maximum number of sort groups is 64.
ONLINE CONFIGURATION
Online configuration allows the ECS user to directly recover
configuration information from the matrix and update the matrix
configuration used by ECS. All the Online Configuration facilities
require an ethernet connection to the matrix.
Online mode is described in more detail in chapter 9 of this manual.
MATRIX HARDWARE SETUP
To begin configuring the matrix hardware open the ‘Hardware’ menu
and select the ‘Cards and Ports’ link to open the hardware
configuration screen.