Fixed group tallies, Fixed group tallies -74, Figure 5-6 fixed group soft mode options -74 – Clear-Com Eclipse-Omega User Manual
Page 184
Clear-Com
Eclipse Configuration Software Instruction Manual
5 - 7 4
• Protect Port from Assignment. When this option is enabled the
port cannot be locally assigned as a talk/listen key by another
panel.
5. Select the drop down arrow and set the required status (True or
False). The status box will be checked or unchecked to indicate
True or False.
Figure 5-6: Fixed Group Soft Mode Options
FIXED GROUP TALLIES
To enable/disable Tallies
1. Open the Fixed Groups screen by selecting the ‘Fixed Groups’ link
on the Configuration menu.
2. Create a Fixed Group or select a Fixed Group that was been
previously created.
3. Expand the ‘Tallies’ item in the ‘Properties’ window.
4. Select the ‘In Use Tally’ item in the ‘Tallies’ list.
5. Select the drop down arrow and select the required status.
This allows the system to set a tally (flashing LED) on all the panel
keys that are assigned to the Fixed Group whenever a talk is active on
the Fixed Group. In the case of multiple matrices in a linked set the ‘In
Use’ tally is broadcast to all other systems in the linked set. In this
way the feature is seamless over the matrices in a linked set.
The default is disabled.