Drive overtemperature fault, Motor overtemperature fault, Drive cooling fault – Rockwell Automation 1784-PM16SE SoftLogix Motion Card Setup and Configuration Manual User Manual

Page 372: Drive control voltage fault, Feedback fault, Commutation fault, Drive overcurrent fault, Drive overvoltage fault, Drive undervoltage fault

background image

Publication 1784-UM003A-EN-P – June 2003

364 Motion Object Attributes

Drive Overtemperature Fault

The Drive Overtemperature Fault bit is set when the drive’s temperature
exceeds the drive shutdown temperature.

Motor Overtemperature Fault

The Motor Overtemperature Fault bit is set when the motor’s temperature
exceeds the motor shutdown temperature.

Drive Cooling Fault

The Drive Cooling Fault bit is set when the ambient temperature surrounding
the drive’s control circuitry temperature exceeds the drive ambient shut-down
temperature.

Drive Control Voltage Fault

The Drive Control Voltage Fault bit is set when the power supply voltages
associated with the drive circuitry fall outside of acceptable limits.

Feedback Fault

The Feedback Fault bit is set when one of the feedback sources associated
with the drive axis has a problem that prevents the drive from receiving
accurate or reliable position information from the feedback device.

Commutation Fault

The Commutation Fault bit is set when the commutation feedback source
associated with the drive axis has a problem that prevents the drive from
receiving accurate or reliable motor shaft information to perform
commutation.

Drive Overcurrent Fault

The Drive Overcurrent Fault bit is set when drive output current exceeds the
predefined operating limits for the drive.

Drive Overvoltage Fault

The Drive Overvoltage Fault bit is set when drive DC bus voltage exceeds the
predefined operating limits for the bus.

Drive Undervoltage Fault

The Drive Undervoltage Fault bit is set when drive DC bus voltage is below
the predefined operating limits for the bus.