Position Lock Status

The Position Lock Status bit attribute is set when the magnitude of the axis
position error has become less than or equal to the configured Position Lock
Tolerance value for the associated physical axis. If this bit is not set then the
magnitude of the axis position error is greater than the configured Position
Lock Tolerance value.

Power Limit Status

The Power Limit Status bit attribute is set when the magnitude of the actual
supplied power is greater than the configured Power Threshold.

Axis Control Bit Attributes

Abort Process

When the Abort Process bit is set, any active tuning or test process on the
drive axis is aborted

Shutdown Request

When the Shutdown Request bit is set, the drive axis is forced into the
shutdown state.

Abort Home Request

When the Abort Home Request bit is set, any active homing procedures are
cancelled.

Abort Event Request

When the Abort Event Request bit is set, any active registration or watch event
procedures are cancelled.

GSV/SSV Access

Attribute Name

Data Type

Values

GSV

Axis Control Bits

DINT

0:Abort Process Request
1: Shutdown Request
2: Reserved
3: Abort Home Request
4: Abort Event Request
5-14: Reserved
15: Change Cmd Reference
16-31: Reserved