Module identity, Refresh, Reset module – Rockwell Automation 1784-PM16SE SoftLogix Motion Card Setup and Configuration Manual User Manual
Page 212

Publication 1784-UM003A-EN-P – June 2003
204 Configuring a 1394x-SJTxx-D Digital Servo Drive
Module Identity
This field does not take into account the Electronic Keying or Minor Revision
selections for the module that were specified on the General Tab.
Refresh
Click on this button to refresh the tab with the new data from the module.
Reset Module
Click on this button to return a module to its power-up state by emulating the
cycling of power.
Displays:
If the module in the physical slot:
Match
agrees with what is specified on the General Tab. In order
for the Match condition to exist, all of the following must
agree: Vendor Module Type (the combination of Product
Type and Product Code for a particular Vendor) Major
Revision
Mismatch
does not agree with what is specified on the General Tab
ATTENTION
!
Resetting a module causes all connections to or through the
module to be closed; this may result in loss of control.