Requested packet interval, Inhibit module – Rockwell Automation 1784-PM16SE SoftLogix Motion Card Setup and Configuration Manual User Manual
Page 252
Publication 1784-UM003A-EN-P – June 2003
244 Configuring an 8720MC Drive
On this tab, you can:
• Select a requested packet interval.
• Choose to inhibit the module.
• Configure the controller so loss of the connection to this module causes
a major fault.
• View module faults.
Requested Packet Interval
Does not apply to this setup. Field is greyed out.
Note: This field is disabled for all motion modules (e.g., 1784-PM02AE,
1784-PM16SE modules and all 1394-, Ultra3000, Kinetix 6000, and
8720MC drives).
Inhibit Module
Check/Uncheck this box to inhibit/uninhibit your connection to the module.
Inhibiting the module causes the connection to the module to be broken.
Note: Inhibiting/uninhibiting connections applies mainly to direct
connections, and not to the CNB module.
When you check this box and go online, the icon representing this module in
the controller organizer displays the Warning Icon.
TIP
The data on this tab comes directly from the controller.
This tab displays information about the condition of the
connection between the module and the controller.
ATTENTION
!
Inhibiting the module causes the connection to the module
to be broken and may result in loss of data.