Motion Object Attributes 353

Pos./Neg. Dynamic Torque Limit

These parameters represent the currently operative maximum positive and
negative torque/current limit magnitude. Each value should be the lowest
value of all torque/current limits in the drive at a given time. These limits
include the amplifier peak limit, motor peak limit, user current limit, amplifier
thermal limit, and the motor thermal limit.

Motor Capacity

This parameter displays the present utilization of motor capacity as a percent
of rated capacity.

Drive Capacity

This parameter displays the present utilization of drive capacity as a percent of
rated capacity.

Power Capacity

This parameter displays the present utilization of the axis power supply as a
percent of rated capacity.

Bus Regulator Capacity

This parameter displays the present utilization of the axis bus regulator as a
percent of rated capacity.

Motor Electrical Degrees

This parameter is the present electrical angle of the motor shaft.

GSV/SSV Access

Attribute Name

Data Type

Values

GSV

Pos. Dynamic Torque Limit
Neg. Dynamic Torque Limit

REAL

%Rated

GSV/SSV Access

Attribute Name

Data Type

Values

GSV

Motor Capacity

REAL

%

GSV/SSV Access

Attribute Name

Data Type

Values

GSV

Drive Capacity

REAL

%

GSV/SSV Access

Attribute Name

Data Type

Values

GSV

Power Capacity

REAL

%

GSV/SSV Access

Attribute Name

Data Type

Values

GSV

Bus Regulator Capacity

REAL

%

GSV/SSV Access

Attribute Name

Data Type

Values

GSV

Motor Electrical Angle

REAL

Degrees